Dew Point Calculator
Water condenses on any surface colder than the air's dew point. Enter the room temperature and relative humidity for the dew point, then the outdoor temperature and the R-value of a wall or window to see how cold its inside surface gets, whether it will sweat, and the highest indoor humidity it can take.
Your project
Whole-assembly R including air films. Windows are rated by U-factor: R = 1 ÷ U (a U-0.30 window is R-3.3). Leave blank for the dew point only.
Your results
- Dew point
- 44.6 °F
- 7 °C — any surface at or below this collects water
- Inside surface temperature
- 53 °F
- Condensation on that surface
- No — 8.4 °F above the dew point
- Highest indoor humidity before it condenses
- 55% RH
Estimates use typical US material and labor pricing. Confirm quantities against the coverage chart on the bag before you buy.
Gear for this job
As an Amazon Associate I earn from qualifying purchases. Product links on this page may earn us a commission at no extra cost to you.
Prices as of Oct 1, 2026, 4:38 AM UTC. Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon.com at the time of purchase will apply to the purchase of this product.
How this calculator works
- γ = ln(RH/100) + 17.625 × T / (243.04 + T), with T in °C
- Dew point (°C) = 243.04 × γ / (17.625 − γ) (Magnus form, Alduchov & Eskridge 1996)
- Inside surface °F = Tin − (Tin − Tout) × 0.68 / R-total (0.68 = inside air film, ASHRAE Fundamentals)
- Max RH = 100 × exp(17.625·Ts/(243.04+Ts) − 17.625·Tin/(243.04+Tin)), temperatures in °C
Dew point (°F) at common indoor conditions
| Room temp | 30% RH | 40% RH | 50% RH | 60% RH |
|---|---|---|---|---|
| 65 °F | 32.8 °F | 40.1 °F | 45.9 °F | 50.8 °F |
| 68 °F | 35.4 °F | 42.8 °F | 48.7 °F | 53.6 °F |
| 70 °F | 37.1 °F | 44.6 °F | 50.5 °F | 55.5 °F |
| 72 °F | 38.9 °F | 46.4 °F | 52.3 °F | 57.4 °F |
| 75 °F | 41.5 °F | 49 °F | 55.1 °F | 60.2 °F |
Computed with this calculator's Magnus formula.
Inside surface temperature at 70 °F indoors, 20 °F outdoors
| Assembly R-value | Surface °F | Condenses above |
|---|---|---|
| R-1 | 36 °F | 29% RH |
| R-2 | 53 °F | 55% RH |
| R-3.3 | 59.7 °F | 70% RH |
| R-5 | 63.2 °F | 79% RH |
| R-15 | 67.7 °F | 93% RH |
Computed: steady state, inside air film R-0.68. Window edges and frames run colder than the centre of the glass.
Why the surface temperature matters more than the air
Condensation forms where a surface is at or below the dew point, not where the air is. Room air at 70 °F and 40% RH has a dew point of about 44.6 °F, so it only wets a surface that cold. On a 20 °F night, a surface with R-2 overall — roughly an older double-pane window — sits near 53 °F inside, above that dew point. A single-pane window, at about R-1, drops to about 36 °F and runs with water.
The inside surface temperature comes from the ratio of the inside air film (R-0.68 in the ASHRAE Handbook of Fundamentals) to the whole assembly's R-value. More insulation raises the inside surface temperature; a cold spot such as a thermal bridge, a missing batt or a window frame lowers it locally.
Inside the wall
The same rule applies to layers inside a wall: warm, moist indoor air that leaks into the cavity condenses on the first surface colder than its dew point, often the back of the exterior sheathing. The fix is air sealing first, a vapor retarder where your climate calls for one, and enough exterior insulation to keep the sheathing warm. The wall assembly R-value calculator totals the layers.
Formula and accuracy
The calculator uses the Magnus approximation with Alduchov and Eskridge's 1996 coefficients (17.625 and 243.04 °C), which stays within about 0.1 °C of the full saturation vapor pressure equations between −40 and 50 °C. Surface temperatures are steady-state estimates; real surfaces vary with air movement, sun and thermal bridges.
Frequently asked questions
What is the dew point at 70 degrees and 40% humidity?
About 44.6 °F (7.0 °C). Any surface in the room colder than that, such as a single-pane window on a cold night, will collect condensation.
How do you calculate dew point from temperature and humidity?
Convert to °C, compute γ = ln(RH/100) + 17.625·T/(243.04 + T), then dew point = 243.04·γ/(17.625 − γ). At 21.1 °C and 40% RH, γ = 0.492 and the dew point is 7.0 °C (44.6 °F).
Why do my windows sweat in winter?
The glass is colder than the dew point of the room air. At 70 °F indoors and 20 °F outside, a single-pane window (about R-1) sits near 36 °F, below a 40% RH dew point of 44.6 °F. Lower the humidity, improve the window, or keep air moving across the glass.
What indoor humidity is safe in winter?
It depends on your coldest surface. Enter the outdoor temperature and the R-value of your windows or walls: the calculator gives the highest relative humidity that surface can take before it condenses.
Does insulation stop condensation?
It helps by keeping inside surfaces warmer, but air sealing matters as much. Moist indoor air leaking into a wall condenses on the cold sheathing no matter how much insulation is in the cavity.